Wellbore Genius
Help

Live Pumping

Open a Builder schedule and press Start, attach a live DAQ feed, replay a saved session, or run synthetic for training.

SourceSynthetic
Idle· last sample No samples yet
Pressure
Length
Temp
Source
1.00×
tick 400 ms · 1.25 sim-min / real-sec

Deferred production ledger

Last 24 h · gas @ $3.40 / Mcf · 0 lifetime events

24h$0.000 evt

No events in the last 24 h. Log the next screen-out or ISIP anomaly below to start building the ops-review ledger.

Saved sessions

No saved sessions yet. Save the current run to replay it later or share via JSON.

Live Pumping — plan vs. actual

SCREENOUT OK · 0%
Idle
Live-pumping chart customization
Awaiting telemetry…

Why this risk score?

OK
  • Not enough samples yet.
Samples0
Plan duration53.0 min
Plan rate now0.0 bpm

Wellbore displacement / pad clock

No geometry — using 4.0 in × 11000 ft demo string
Pumped [bbl]
0
Wellbore vol [bbl]
171
Time-to-perfs [min]
First sand at perfs
Flush remaining [bbl]
0
Flush ETA [min]
Perfs 11000 ftSurfaceTD 11000 ft
Pumped banks0
No banks yet
Pad
Slurry
Pre-flush
Post-flush
Waiting for pumping to begin…
Customize chartaxis · series · theme · presets
Chart customization

Plan deltas — rate & proppant concentration

Drift from plan over time. Green = on plan, amber = watch, red = out of band.

Rate Δ [bpm]:
Ppa Δ [ppa]:
Awaiting telemetry…
Loading source breakdown…

Nolte-Smith net-pressure

Awaiting fit
Auto · inferred 0.00 min
slope m =
· n 0
Presets are scoped to job live-pumping
No samples with Pnet > 0 and t > pump-start.

Decline analysisMethod

Waiting for shut-in data — at least 4 BHP samples required.

Entry-friction distribution
Rolling P10/P50/P90 of Δpperf per cluster from recent step-downs.
demo data
Cluster 1P50 460 psi (n=3)
Cluster 2P50 640 psi (n=3)
Cluster 3P50 330 psi (n=3)
Cluster 4P50 840 psi (n=3)
Overall P50 560 psi across 12 step-downs.
DFIT pre-closure interpreter
Log-log slope of |dp/dt| vs t classifies the diagnostic regime.
awaiting shut-in
Waiting for a sustained shut-in (rate < 0.5 bpm for ≥3 samples).
No clean diagnostic regime detected.
Wellbore fluid-front player
Scrub through the pumped-bank displacement (demo schedule).
t = 5.6 min · 336 bbl
SurfaceTD 11000 ft
Pre-flushPadSlurry 0.5 ppaSlurry 1.5 ppaFlush

ISIP auto-pick

Detects shut-in on the live feed and reports instantaneous shut-in pressure.

Waiting for shut-in…

Live alarms

Configurable threshold / slope / differential / spike rules over the rolling sample buffer.

Rules
threshold
Amber severity.
rate-of-change
Critical severity.
rate-of-change
Watch severity.
Fired (0)

No active alarms.

Microseismic events

Classifies each event as induced / natural / cultural-noise / unclassified using stage proximity, depth and pick confidence. GTC-Analytics RaNDL parity.

No microseismic events loaded. Import a CSV or load the sample stream to see classifier output.

NPT / NPP rollup

Pumping vs non-productive minutes over the current sample buffer.

Utilization
0.0%
Pumping [min]
0.0
Wireline [min]
0.0
NPT [min]
0.0
pumpingrampupshut-inwirelinenpt
Wireline activity
Pump-side fallback (no depth feed)
No segments
Customize chartaxis · series · theme · presets
Chart customization

G-function viewer

Nolte G-time + semilog derivative (BHP & G·dP/dG vs G). Tangent-line closure pick.

Toggle on after pumping has stopped to analyze the shut-in falloff.

Job Pilot
Paused
Gate off
0
0
0
✓ telemetry
TLPNo TLP signal
hover or focus badges for details
Hold
manual

All signals nominal — hold current rate.

Trigger: all signals nominal

Decision rationale (signal × threshold)

Keyboard: Tab into tiles or trigger labels · ←/→/↑/↓ to move · Enter/Space to pin · Esc to clear. Global: Alt+R / Alt+Shift+R cycle rationale · Alt+T / Alt+Shift+T cycle audit triggers · Alt+P pin · Alt+C clear.

Test scenarios (drive fusion + audit)

Each scenario routes through fuseJobPilotSignals and appends an entry to the audit log below.

Auto-apply (opt-in)

Shut-in always requires manual operator action.

Audit log (0)