Settings
User preferences are stored locally on this browser. Use Reset to default values on any card to clear that preference and restore the shipped default.
Account
Cloud sync
Offline cache
| Kind | Entries | Size | Newest | Action |
|---|---|---|---|---|
| Loading… | ||||
| Kind | Hits | Misses | Stored | Hit rate |
|---|---|---|---|---|
| Manuals | 0 | 0 | 0 | — |
| Scenarios | 0 | 0 | 0 | — |
| DFIT benchmarks | 0 | 0 | 0 | — |
| Verification examples | 0 | 0 | 0 | — |
Appearance
Currently applied: dark
Palette
Accent and surface flavor. Rides on top of the Light / Dark mode above.
Working style
Units
Per-dimension overrides
Auto follows the unit system above. Pin a dimension to keep it on a specific unit even when the system flips.
Live preview
Seeded with 1 ft · 1,000 psi · 100 °C and stored as canonical SI. Flip the system or pin a dimension above and these fields re-render in the new units — the choice survives a page refresh.
Validation visuals
Current state: On · Default: On
RTA
Reduce RTA focus flash
Shortens or disables the ember ring pulse that appears when jumping to a field in the RTA section search. Also respects your system prefers-reduced-motion setting.
Builder right rail
Operating envelope
Higher is worse — amber then red as the value rises.
Higher is worse — amber then red as the value rises.
Lower is worse — amber then red as the value falls.
Lower is worse — amber then red as the value falls.
Lower is worse — amber then red as the value falls.
Pad scheduler
Current: Exact (drop unmatched perfs) · Default: Exact (drop unmatched perfs)
Report branding (global)
Global report branding
Solver
Thread the in-house transient single-phase Darcy grid into every Newton iterate of live DFIT runs (KGD / PKN / Carter). Off → legacy PDL-only path.
Substitute the single-phase grid with the Phase 14 3-phase black-oil IMPES kernel (oil/gas/water + Standing/Vasquez-Beggs PVT + optional energized-CO₂ gas-FVF bridge). Off → fall back to single-phase coupling above.
Enable enthalpy-specified (PH) and entropy-specified (PS) flash in the Choke advisor and EGS injector advisor. On: choke pressure drops use constant-enthalpy Joule–Thomson cooling; geothermal injectors follow isentropic adiabats and steam quality. Off: legacy pressure-temperature flash with a tabulated JT approximation.
AI copilots
AI copilot models
Pin a specific gateway model per copilot surface, or leave on the recommended tier. Overrides are stored locally on this browser and read by the server only when the matching surface sends a request.
Engineer Copilot
Best quality · slower · higher cost· default (reasoning)
Setup Assistant
Recommended · balanced quality + latency· default (balanced)
Design Copilot
Best quality · slower · higher cost· default (reasoning)
Diagnostic Studies attribution
Best quality · slower · higher cost· default (reasoning)
Forecast Narrative
Recommended · balanced quality + latency· default (balanced)
Driller's Copilot
Recommended · balanced quality + latency· default (balanced)
Command Palette ✨ picks
Fastest · lowest cost · short prompts· default (fast)
AI Author
Recommended · balanced quality + latency· default (balanced)
Live-Pumping Operator Copilot
Recommended · balanced quality + latency· default (balanced)
Voice
Enable confirmation
Off → the result is spoken immediately. On → the metric label flashes on the dock for the delay below before speaking.
Confirmation delay
800 msEnable audio cue
Off → only the voice speaks. On → a brief 880 Hz tone plays first, then the voice reads the metric.
Capped well below clipping — even 100% stays comfortable in a quiet office.
SDK & REST API
Mint bearer tokens for the public SDK at /api/public/sdk/v1/*. Admins only. Keys are team-scoped.
Existing keys
Loading…
Reset
- Appearance (light / dark / system)
- Worst-residue highlight (★)
- DFN clamp envelope multipliers
- DFN clamp impact thresholds
- DFN unit-roundtrip tolerance